CPT1006-485 converter with 6 inputs for 2- or 3-wire Pt100 probes to RS485 communication with Modbus protocol: isolated analogue inputs, detection of broken Pt100 and compensation wire, and individual enabling of each probe. 24 VDC galvanically isolated power supply and DIN rail mounting.
| Inputs: |
6 x Pt100 (2 or 3 wires) |
| Communication: |
RS485 · Modbus |
| Mounting: |
35 mm DIN rail |
Features
- ✓6 inputs for 2- or 3-wire Pt100 probes
- ✓Analogue inputs isolated from communication and power supply
- ✓Detection of broken Pt100 and compensation wire
- ✓RS485 communication with Modbus protocol
- ✓Individual enabling of each probe
- ✓24 VDC power supply (18 … 75 VDC) with galvanic isolation
- ✓35 mm DIN rail mounting (EN 60715)
Frequently asked questions
Can 2-wire Pt100 probes be connected?
Yes: for a 2-wire Pt100, join the compensation wire terminal to the Pt100 common.
Which data are read via Modbus?
The temperature of each of the 6 probes, the enabled probes and the probe error.
What happens if a probe breaks?
The unit detects a broken Pt100 or compensation wire and reports it as a probe error.