MCIV02 · DIGITAL INTENSITY CONTROL WITH BUILT-IN TOROIDAL



DIGITAL INTENSITY CONTROL WITH BUILT-IN TOROIDAL



MCIV02 digital current control with built-in toroid up to 20 A: maximum and minimum setpoints, programmable alarms and stop output.

Product type: Digital current control with display
Installation: DIN rail
Measurement: Built-in toroid, up to 20 A
Application: Machine stop on consumption out of setpoint

Features

  • ✓Built-in toroid: no external current transformer
  • ✓Maximum and minimum current control with programmable setpoints
  • ✓Alarms for maximum, minimum, in range and out of range
  • ✓Programmable hysteresis
  • ✓Timed or latched alarm, with time adjustable in seconds, minutes or hours
  • ✓Machine stop output and 2 alarm outputs
  • ✓Display with current reading
Supply
24…230 VAC · 12/24 VDC
Outputs
Stop 8 A + 2 alarms 5 A
Measurement
Up to 20 A · toroid
Mounting
DIN rail

How it works

  1. 1The load cable is passed through the built-in toroid: no external transformer is needed.
  2. 2The maximum and minimum setpoints, the hysteresis and the alarm type are programmed.
  3. 3When the current leaves the setpoint range, the alarms and the stop output act.
  4. 4In timed mode the alarm lasts for the set time; in latched mode it stays until reset.

Frequently asked questions

Up to what current does it measure?

Up to 20 A, with the built-in toroid.

Which alarm types does it have?

Maximum, minimum, in range and out of range, in timed or latched mode.

How does it differ from the ZCI relays?

The MCIV02 has a display, programmable maximum and minimum setpoints, alarms and a stop output; the ZCI relays are set by potentiometer and take 1 DIN module.


General information

Reference MCIV02  (24 / 48 / 110 / 230 VAC · 12 / 24 VDC)
Series M · DIN rail
Product type Digital current control with display

Electrical specifications

Supply 24 / 48 / 110 / 230 VAC · 12 / 24 VDC
Consumption 2.8 VA
Stop output 1 x SPDT 8A
Alarm outputs 2 x SPST 5A

Measurement

Input Built-in toroid
Range Up to 20 A

Alarms

Types Maximum, minimum, in range and out of range
Hysteresis Programmable
Modes Timed or latched
Alarm time Adjustable in seconds, minutes or hours

Housing and mounting

Dimensions 90 × 62.5 × 53 mm
Fixing DIN rail
Connection Plug-in connectors
Material Grey polycarbonate UL94-V0
Weight ≈ 170 g

Environmental conditions

Operating temperature −10 to +55 °C
Storage temperature −25 to +85 °C

Standards and certifications

Compliance CE · 2014/35/EU · 2014/30/EU