XTDU312 digital percentage doser: sets the % of ON time from 0 to 100 % on a 1 s or 1 min base. 48 × 48 panel, IP65 front.
What is a percentage timer?
A cyclic timer in which you set what percentage of each cycle the output is on, over a 1 s or 1 min base.
What is it used for?
For proportional dosing: dosing pumps, heaters or valves that must work a percentage of the time.
Which socket does it use?
An 11-pin socket: ZB11-0 for DIN rail, PG11 with screw or TBEU1E in-line.
ZB11-0 · 11-pin socket for DIN rail · PG11 · 11-pin socket with rear screw · TBEU1E · 11-pin in-line socket · MA7248 · frame from 72 × 72 to 48 × 48 mm · MA9648 · frame from 96 × 96 to 48 × 48 mm · MA96D48 · frame from 96 × 48 to 48 × 48 mm
The detailed diagram is in the datasheet.