Processes >

MBA401RR-C · BARRIER CONTROL WITH COMMUNICATION



MBA401RR-C BARRIER CONTROL WITH COMMUNICATION



MBA401RR-C barrier control with Modbus communication: raising and lowering, signal light and automatic or local mode.

Product type: Barrier control with communication
Operation: Raise and lower pulses
Signalling: 2-lamp traffic light
Modes: Automatic (Modbus) or local

Features

  • ✓Controls the barrier movement with raise and lower pulses
  • ✓Controls the signal light
  • ✓Upper and lower limit switch inputs
  • ✓Automatic operation over Modbus or manual operation from the unit
  • ✓Operation status on the display and over Modbus
  • ✓Keeps the operating mode and any unfinished sequence after a power cut
Supply
24 V AC/DC
Communication
Modbus RTU · RS-485
Outputs
250 VAC · 2 A
Mounting
DIN rail or wall

How it works

  1. 1On power-up, RUN lights up, the identifier is shown for 2 seconds and the unit returns to its last mode, automatic or local.
  2. 2In automatic, the Modbus master sends commands (40,000 registers) and reads the status (30,000 registers).
  3. 3To switch to local, ENTER is held for 5 seconds; the menu starts lowering, raising or the return to automatic.
  4. 4The upper and lower limit switches show when each movement ends.

Frequently asked questions

What does it control?

The barrier movement, with raise and lower pulses, and the signal light.

How does it communicate?

Over Modbus RTU on RS-485. The 30,000 registers can always be read; commands in the 40,000 registers are only accepted in automatic mode.

What if power fails mid-movement?

It keeps the operating mode and the unfinished raise or lower sequence.


General information

Reference MBA401RR-C  (24 V AC/DC)
Series M · DIN rail or wall
Product type Barrier control with communication

Electrical specifications

Supply 24 V AC/DC
Outputs 250 VAC · 2 A: raise pulses, lower pulses and 2 signal lamps
Inputs Upper and lower limit switch

Functions

Modes Automatic (Modbus) · local (unit menu)
Local commands Lower barrier · raise barrier · back to automatic
Memory Operating mode and unfinished sequence

Communication

Protocol Modbus RTU
Interface RS-485, with end-of-line jumper
Registers 30,000 status reading · 40,000 commands (automatic only)

Indications

LEDs RUN, LOCAL, AUTO and COM
Display Limit switches and active raise or lower cycle

Housing and mounting

Dimensions 105.5 × 90.5 × 58.5 mm
Fixing DIN rail or wall

Standards and certifications

Compliance CE