Compressors

Sectors

Compressors


Units for controlling piston and screw compressors: star-delta starting, motor protection, timed drains, operating temperature and running hours for oil changes and servicing. On special units we add the parameters the manufacturer asks for.

Featured product

XVDU071 hour totalizer with alarm

Counts the compressor's running hours and switches an alarm output when the programmed hours are reached: ideal for oil, filter and service reminders.

8 digitswith 2 decimals Partial + totalprogrammable alarm 8 Aalarm output 48 × 48 mm11-pin socket
Reset Front and external
Alarm Total and partial alarm programming
Supply 12 VDC · 24 VDC · 24 VAC · 48 VAC · 110 VAC · 230 VAC

View the XVDU071 page →

What to control on a compressor, and with which unit

Machine or installation What to control Unit
Compressor motor above 5.5 kW Star-delta starting with changeover pause
VETV02
pause 0.02 – 2 s, 16 A
ZETV02
17.5 mm, 2 voltages
Compressor with unloader valve Unloaded start and delayed loading
ZMMV11
on-delay
VIE010
off-delay interval
Receiver and separator Automatic drain at set intervals for a few seconds
XTDU303 / XTDC303
asymmetrical cyclic
ZMCV11
cyclic, DIN rail
Compressor motor Phase sequence and phase failure
ZCFF02A
0.5 s delay
Compressor motor Overload due to excess current
ZCIx5xx
maximum current
MCIV02
maximum and minimum alarms
Motor and head Operating temperature
VCM010
PTC thermistor
MCT403
Pt100, with pre-warning
XCT65Bxx
Pt100 controller with alarm
Plant with 2 or 3 compressors Alternation to share running hours
TABV02
2 compressors
TABV03
3 compressors
Refrigeration and HVAC compressor Anti-short-cycle delay between starts
ZMMV11
0.1 s – 10 days
Maintenance Running and idle hours, oil change
XVDU071
total and partial alarm
STDU009
partial + total

Need a special function?

On special units we add the parameters you need to monitor: loaded and idle hours, pressure, alarms or communication with the panel.

Request a quoteEngineering and design

Frequently asked questions

Which unit gives an oil change reminder on a compressor?

The XVDU071: hour totalizer with alarm output and total and partial alarm programming.

Which star-delta starter do you recommend?

The VETV02, with a star-to-delta pause adjustable from 0.02 to 2 seconds and 16 A contacts, or the ZETV02 in 17.5 mm.

How is the receiver drain automated?

With an XTDU303 / XTDC303 asymmetrical cyclic timer, which sets the drain time and the time between drains separately.

See also:  Vacuum pumps  ·  Air conditioning control  ·  Price list