Textile

Sectors

Textile

Textile


Standard and custom units for yarn, rope and fabric production machinery: counting turns, picks and metres per shift, thread-break detection with photocells, bath and stenter temperature, and ModBus communication to collect production and incident data.

Featured product

SCE485 pulse counter with communication

Counts the output of each machine and sends it over ModBus RTU to the factory system: metres, pieces or turns per shift, with two presets for pre-warning and stop.

ModBus RTURS-485 2presets 5 kHz / 30 Hzcounting filter IP65front protection
Counting 5 counting modes · NPN or PNP inputs
Communication 1200 to 19200 baud · 8N2, 8O1, 8E1 formats
Outputs 8 A 250 VAC · sensor supply

View the SCE485 page →

What to control in the textile industry, and with which unit

Machine or installation What to control Unit
Weaving machine, knitting machine Counting picks or turns and stopping at the end of the piece
XCEU512 / XCEC512
keypad lock
Warping machine, folder, winder Metres produced, speed and hours
SCR 007
metres, m/h and hours
XCEU522 / XCEC522
pulses to metres
Bobbin winder, twister, spinning frame Turns and length per bobbin with non-metric encoders
SCEU011
multiplier 1–99
SCEU015
divider 1–99
SCEU029
scaling factor with decimals
Bobbins with thread-break photocell Break detection and machine stop
Custom unit
designed for the machine
Production per shift Partial count per shift and machine total
XVEU080
partial + total
XVEU070
with front reset
Data collection for the whole plant Production and incidents to the system over ModBus
SCE485
counter with ModBus
XVE110
display with ModBus
CPT1006
6 Pt100 probes with ModBus
Stenter, heat-setting frame Chamber temperature with thermocouple
XCT55Bxx
0–1100 °C
XCT82R
Pt100 / J / K / T, 2 alarms
Dyeing: autoclave, jigger Bath temperature and process times
XCT65Bxx
Pt100 with alarm
XCT83R
controller with timer
Chain or roller speed Alarm on low or high speed
XVEU050
tachometer, 2 presets
XVEU102
with scaling factor
Loom and pump motors Overload, phase and dry running
ZCIx3xx
maximum and minimum
Maintenance Partial and total machine hours
STDU009
partial + total
XVDU071
with alarm

Need a special function?

We design custom units for textile machinery manufacturers: thread-break control, metres per shift and ModBus communication with all production and incident data.

Request a quoteEngineering and design

Frequently asked questions

How is each machine's output sent to the computer?

With the SCE485 counter or the XVE110 display, which communicate over ModBus RTU (RS-485) from 1200 to 19200 baud.

Which counter measures metres with a non-metric encoder?

The SCEU011 (multiplier from 1 to 99), the SCEU015 (divider from 1 to 99) or the SCEU029, with a scaling factor of two integer digits and four decimals.

Which unit shows metres, speed and hours at the same time?

The SCR 007: production metre count, speed in metres per hour and running hour counter.

See also:  Food industry  ·  Compressors  ·  Price list



Return to the list

Automatismos.com